| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 1.750 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 1.906 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 1.000 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 1.500 |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 1.500 |
| AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 500.0 |
| AFGA | OPERATING TEMP RANGE | CELSIUS -40.0 TO 85.0 |
| AHAJ | REFERENCE FREQUENCY PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 1.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 500.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 500.0 |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED CRYSTAL BLANK |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | LOCATION NOT OTHERWISE SPECIFIED BLANK 5.0 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION PIN INPUT 1 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION PIN OUTPUT 1 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | THIRD FUNCTION PIN GROUND 2 |
| CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | FIRST FUNCTION KILOHERTZ 1ST BAND PASS 995.50 |
| CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | FOURTH FUNCTION MEGAHERTZ 4TH BAND PASS 1.01 |
| CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | SECOND FUNCTION KILOHERTZ 2ND BAND PASS 999.98 |
| CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | THIRD FUNCTION MEGAHERTZ 3RD BAND PASS 1.00 |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.112 |
| CRBB | FREQUENCY BAND WIDTH PER FUNCTION | FIRST FUNCTION KILOHERTZ 1ST BAND PASS 999.98 |
| CRBB | FREQUENCY BAND WIDTH PER FUNCTION | SECOND FUNCTION MEGAHERTZ 2ND BAND PASS 1.00 |
| CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | FIRST FUNCTION MINIMUM 1ST BAND PASS 30.0 |
| CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | FOURTH FUNCTION MINIMUM 4TH BAND PASS 30.0 |
| CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | SECOND FUNCTION MAXIMUM 2ND BAND PASS 1.0 |
| CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | THIRD FUNCTION MAXIMUM 3RD BAND PASS 1.0 |
| CRTL | CRITICALITY CODE JUSTIFICATION | CRBB AND CQFC |
| STYL | STYLE DESIGNATOR | |
| TEST | TEST DATA DOCUMENT | DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 18876-10178156 |