| ABHP | OVERALL LENGTH | INCHES MAXIMUM 2.500 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | FIRST MOUNTING FACILITY INCHES NOMINAL 2.125 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SECOND MOUNTING FACILITY INCHES NOMINAL 2.125 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SECOND MOUNTING FACILITY INCHES NOMINAL 1.000 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | FIRST MOUNTING FACILITY INCHES NOMINAL 1.000 |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 2.600 |
| ABMK | OVERALL WIDTH | INCHES MAXIMUM 1.625 |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | FIRST MOUNTING FACILITY INCHES NOMINAL 0.173 |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | SECOND MOUNTING FACILITY INCHES NOMINAL 0.173 |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AJSS | FREQUENCY IN HERTZ | NOMINAL 400.0 |
| AKDX | WINDING QUANTITY | 1 |
| AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
| APCN | COIL QUANTITY | 1 |
| APNP | DUTY TYPE | CONTINUOUS |
| APNQ | ARC QUENCHING METHOD | AIR |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | FIRST MOUNTING FACILITY UNTHREADED HOLE(S) 4 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SECOND MOUNTING FACILITY UNTHREADED HOLE(S) 6 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CBBL | FEATURES PROVIDED | COIL VOLTAGE SUPPRESSION |
| CBME | CUBIC MEASURE | CUBIC INCHES 10.562 |
| CQYJ | MOUNTING FACILITY PATTERN | FIRST MOUNTING FACILITY RECTANGULAR |
| CQYJ | MOUNTING FACILITY PATTERN | SECOND MOUNTING FACILITY RECTANGULAR |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, DOUBLE THROW, ONE POSITION MOMENTARY 2 |
| CRXH | TIME DELAY | FIXED OPERATE TIME SECONDS MAXIMUM 0.02 |
| CRXH | TIME DELAY | FIXED RELEASE TIME SECONDS MAXIMUM 0.05 |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS AC 25 DEG CELSIUS 115.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | INDUCTIVE LOAD AMPERES AC 10.0 AND AMPERES DC 10.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | LAMP LOAD AMPERES AC 2.0 AND AMPERES DC 2.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | MOTOR LOAD AMPERES AC 6.0 AND AMPERES DC 6.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES AC 10.0 AND AMPERES DC 10.0 |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 115.0 AND DC 28.0 |
| TEST | TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-R-6106 |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS SCREW 8 |
| ZZZK | SPECIFICATION/STANDARD DATA | GOVERNMENT STANDARD 96906--S24149 |