| ABHP | OVERALL LENGTH | INCHES MAXIMUM 1.718 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY INCHES MINIMUM 1.396 AND INCHES MAXIMUM 1.446 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY INCHES NOMINAL 0.625 |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 1.352 |
| ABMK | OVERALL WIDTH | INCHES MAXIMUM 1.025 |
| ABTD | MOUNTING SLOT WIDTH | SINGLE MOUNTING FACILITY INCHES NOMINAL 0.150 |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC AND SHOCK RESISTANT AND VIBRATION RESISTANT |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AJSS | FREQUENCY IN HERTZ | NOMINAL 400.0 |
| AKDX | WINDING QUANTITY | 1 |
| AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
| APCN | COIL QUANTITY | 1 |
| APNP | DUTY TYPE | CONTINUOUS |
| APNQ | ARC QUENCHING METHOD | AIR |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY SLOTTED HOLE 4 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CBME | CUBIC MEASURE | CUBIC INCHES 2.381 |
| CQYJ | MOUNTING FACILITY PATTERN | SINGLE MOUNTING FACILITY RECTANGULAR |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION 3 |
| CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | SINGLE WINDING MILLIAMPERES AC 25.0 |
| CRXH | TIME DELAY | FIXED OPERATE TIME SECONDS MAXIMUM 0.02 |
| CRXH | TIME DELAY | FIXED RELEASE TIME SECONDS MAXIMUM 0.04 |
| CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | POLE, DOUBLE THROW, ONE POSITION MOMENTARY 1 |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS AC 25 DEG CELSIUS 230.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | INDUCTIVE LOAD AMPERES AC 10.0 AND AMPERES DC 10.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | LAMP LOAD AMPERES AC 2.5 AND AMPERES DC 2.5 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | MOTOR LOAD AMPERES AC 5.0 AND AMPERES DC 5.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES AC 12.0 AND AMPERES DC 12.0 |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 230.0 AND DC 28.0 |
| CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | LAMP LOAD MILLIAMPERES AC 500.0 AND MILLIAMPERES DC 500.0 |
| CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES AC 2.0 AND AMPERES DC 2.0 |
| PMLC | PRECIOUS MATERIAL AND LOCATION | GOLD TER-INAL SURFACES |
| PRMT | PRECIOUS MATERIAL | GOLD |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS PIN 11 |