| ABHP | OVERALL LENGTH | INCHES MINIMUM 1.005 AND INCHES MAXIMUM 1.025 |
| ABKW | OVERALL HEIGHT | INCHES MINIMUM 1.105 AND INCHES MAXIMUM 1.125 |
| ABMK | OVERALL WIDTH | INCHES MINIMUM 0.505 AND INCHES MAXIMUM 0.525 |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AGAV | END ITEM IDENTIFICATION | LANTIRN MOB S |
| AJSS | FREQUENCY IN HERTZ | MINIMUM 50.0 AND MAXIMUM 400.0 |
| AKDX | WINDING QUANTITY | 1 |
| AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
| APCN | COIL QUANTITY | 1 |
| APNP | DUTY TYPE | CONTINUOUS |
| APNQ | ARC QUENCHING METHOD | AIR |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY PLUG-IN TERMINAL(S) 1 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CBME | CUBIC MEASURE | CUBIC INCHES 0.605 |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, DOUBLE THROW, ONE POSITION MOMENTARY 2 |
| CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | SINGLE WINDING MILLIAMPERES DC 30.0 |
| CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
| CRXH | TIME DELAY | FIXED OPERATE TIME SECONDS MAXIMUM 0.02 |
| CRXH | TIME DELAY | FIXED RELEASE TIME SECONDS MAXIMUM 0.05 |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS AC 25 DEG CELSIUS 115.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | INDUCTIVE LOAD AMPERES AC 8.0 AND AMPERES DC 8.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | LAMP LOAD AMPERES AC 2.0 AND AMPERES DC 2.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | MOTOR LOAD AMPERES AC 4.0 AND AMPERES DC 4.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES AC 10.0 AND AMPERES DC 10.0 |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 115.0 AND DC 28.0 |
| FEAT | SPECIAL FEATURES | FAILURE RATE LEVEL 0.3 PERCENT |
| TEST | TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-R-6106 |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS PIN 8 |
| ZZZK | SPECIFICATION/STANDARD DATA | GOVERNMENT STANDARD 96906--S27401 |