| ABHP | OVERALL LENGTH | 114.5 MILLIMETERS MINIMUM AND 115.5 MILLIMETERS MAXIMUM |
| ABKW | OVERALL HEIGHT | 88.0 MILLIMETERS MINIMUM AND 89.0 MILLIMETERS MAXIMUM |
| ABMK | OVERALL WIDTH | 22.0 MILLIMETERS MINIMUM AND 23.0 MILLIMETERS MAXIMUM |
| AKAE | MAXIMUM OPERATING ALTITUDE RATING | 5000.0 METERS |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| AMQY | INSTALLATION DESIGN | RACK |
| ANPM | INPUT PHASE | SINGLE FIRST OPERATING POWER RQMT |
| ANPM | INPUT PHASE | SINGLE SECOND OPERATING POWER RQMT |
| APNX | INPUT VOLTAGE RATING | 90.0 AC VOLTS MINIMUM AND 264.0 AC VOLTS MAXIMUM FIRST OPERATING POWER RQMT |
| APNX | INPUT VOLTAGE RATING | 120.0 DC VOLTS MINIMUM AND 375.0 DC VOLTS MAXIMUM SECOND OPERATING POWER RQMT |
| APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT |
| APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM SECOND OPERATING POWER RQMT |
| APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM FIRST OPERATING POWER RQMT |
| AYNH | OPERATING AMBIENT TEMP RANGE | -20.0 TO 70.0 CELSIUS |
| BGHY | OUTPUT CONTROL TYPE | FINE VOLTAGE ADJUSTMENT SINGLE POWER OUTPUT |
| BGQR | OUTPUT WATTAGE RATING | 10.0 WATTS NOMINAL SINGLE POWER OUTPUT |
| CBBL | FEATURES PROVIDED | INDICATOR LIGHT AND ROHS DIRECTIVE COMPLIANCE |
| CWGH | OUTPUT CURRENT RATING | 2.000 DC AMPERES NOMINAL SINGLE POWER OUTPUT |
| CWGW | POWER SUPPLY OUTPUT CURRENT/VOLTAGE CHARACTERISTICS | CONSTANT CURRENT AND CONSTANT VOLTAGE SINGLE POWER OUTPUT |
| CWGZ | RIPPLE VOLTAGE AT FULL LOAD | 50.0 MILLIVOLTS PEAK SINGLE POWER OUTPUT |
| CWHF | OUTPUT CONNECTION QUANTITY | 1 SINGLE POWER OUTPUT |
| CWHJ | OUTPUT CONNECTION TYPE | SCREW SINGLE POWER OUTPUT |
| CWHM | INPUT CURRENT RATING | 0.13 AC AMPERES NOMINAL SECOND OPERATING POWER RQMT |
| CWHM | INPUT CURRENT RATING | 0.20 AC AMPERES NOMINAL FIRST OPERATING POWER RQMT |
| CWHQ | INPUT CONNECTION TYPE | SCREW FIRST OPERATING POWER RQMT |
| CWHQ | INPUT CONNECTION TYPE | SCREW SECOND OPERATING POWER RQMT |
| CWHT | INPUT CONNECTION QUANTITY | 1 SECOND OPERATING POWER RQMT |
| CWHT | INPUT CONNECTION QUANTITY | 1 FIRST OPERATING POWER RQMT |
| CWKG | VENTILATION DESIGN TYPE | CONVECTION |
| CWWY | POWER SUPPLY EFFICIENCY LINE | 73.0 |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | DNR SERIES - AC/DC DIN RAIL POWER SUPPLY (PSU) |
| FEAT | SPECIAL FEATURES | INPUT PROTECTION: INTERNAL FUSE T2A, 250 VAC FITTED IN LINE. OUTPUT VOLTAGE TRIM: 4.50 TO 5.75 V. |