| AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
| AARX | INSIDE DIAMETER | 1.500 INCHES NOMINAL |
| ABJH | TEMP RATING | 400.0 FAHRENHEIT SINGLE RESPONSEUNABLE TO DECODE |
| ABKG | BOLT CIRCLE DIAMETER | 3.125 INCHES NOMINAL SECOND ENDUNABLE TO DECODE |
| ABKG | BOLT CIRCLE DIAMETER | 3.875 INCHES NOMINAL FIRST ENDUNABLE TO DECODE |
| ABKU | FLANGE THICKNESS | 0.500 INCHES NOMINAL FIRST ENDUNABLE TO DECODE |
| ABKU | FLANGE THICKNESS | 0.500 INCHES NOMINAL SECOND ENDUNABLE TO DECODE |
| ABKV | OUTSIDE DIAMETER | 2.359 INCHES NOMINAL |
| ACKH | MINIMUM INSIDE BENDING RADIUS | 13.000 INCHES |
| ADJL | INNER CONVEYING TUBE STYLE | ANNULAR CLOSE-PITCH CORRUGATED |
| ADKX | ANGLE BETWEEN RIGID ELBOW FITTINGS IN DEG | 105.0 |
| AECS | BOLT HOLE QUANTITY | 4 FIRST ENDUNABLE TO DECODE |
| AECS | BOLT HOLE QUANTITY | 4 SECOND ENDUNABLE TO DECODE |
| AEPR | FLANGE OUTSIDE DIAMETER | 4.250 INCHES NOMINAL SECOND ENDUNABLE TO DECODE |
| AEPR | FLANGE OUTSIDE DIAMETER | 5.000 INCHES NOMINAL FIRST ENDUNABLE TO DECODE |
| AHNC | CONNECTION STYLE | RAISED SWIVEL FIRST ENDUNABLE TO DECODE |
| AHNC | CONNECTION STYLE | RAISED SWIVEL SECOND ENDUNABLE TO DECODE |
| AHNX | BOLT HOLE DIAMETER | 0.625 INCHES NOMINAL FIRST ENDUNABLE TO DECODE |
| AHNX | BOLT HOLE DIAMETER | 0.625 INCHES NOMINAL SECOND ENDUNABLE TO DECODE |
| AJED | RAISED FACE HEIGHT | 0.133 INCHES NOMINAL SECOND ENDUNABLE TO DECODE |
| AJED | RAISED FACE HEIGHT | 0.140 INCHES NOMINAL FIRST ENDUNABLE TO DECODE |
| AJEE | RAISED FACE DIAMETER | 2.000 INCHES NOMINAL SECOND ENDUNABLE TO DECODE |
| AJEE | RAISED FACE DIAMETER | 2.875 INCHES NOMINAL FIRST ENDUNABLE TO DECODE |
| AKUT | END FLANGE CONSTRUCTION | SOLID FIRST ENDUNABLE TO DECODE |
| AKUT | END FLANGE CONSTRUCTION | SOLID SECOND END |
| AKUU | END CONNECTION DESIGN | ELBOW SECOND END |
| AKUU | END CONNECTION DESIGN | ELBOW FIRST END |
| AWLS | CONNECTION TYPE | RAISED FACE FLANGE FIRST END |
| AWLS | CONNECTION TYPE | RAISED FACE FLANGE SECOND END |
| CQBD | BURST TEST PRESSURE | 400.0 POUNDS PER SQUARE INCH |
| CQQF | OPERATING PRESSURE | 100.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| CRDW | HYDROSTATIC TEST PRESSURE | 200.0 POUNDS PER SQUARE INCH |
| CRFY | FLOW ANGLE | 45.0 DEGREES FIRST END |
| CRFY | FLOW ANGLE | 90.0 DEGREES SECOND END |
| CRXX | MEASURING METHOD AND LENGTH | 31.500 INCHES NOMINAL WORKING |
| CTCJ | FLANGE STYLE | ROUND W / BOLT HOLES FIRST END |
| CTCJ | FLANGE STYLE | ROUND W / BOLT HOLES SECOND END |
| CTCJ | FLANGE STYLE | UNABLE TO DECODE |
| FEAT | SPECIAL FEATURES | A 90 DEG ELBOW IS LOCATED 16.031 IN. FROM FIRST END AND 15.469 IN. FROM SECOND END |
| SCMP | ITEM STRUCTURAL COMPOSITION | BRAIDED NICKEL COPPER ALLOY WIRE OUTER LAYER |