| AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
| ABJT | TERMINAL LENGTH | 1.275 INCHES MINIMUM AND 1.275 INCHES MINIMUM AND 1.625 INCHES MAXIMUM1.625 INCHES MAXIMUM |
| ADAQ | BODY LENGTH | 0.391 INCHES MINIMUM AND 0.421 INCHES MAXIMUM |
| ADAR | BODY OUTSIDE DIAMETER | 0.125 INCHES MINIMUM AND 0.125 INCHES MINIMUM AND 0.155 INCHES MAXIMUM0.155 INCHES MAXIMUM |
| AEBT | TERMINAL DIAMETER | 0.025 INCHES NOMINAL0.025 INCHES NOMINAL |
| AEHX | MAXIMUM POWER DISSIPATION RATING | 125.00 MILLIWATTS125.00 MILLIWATTS |
| AEHY | AMBIENT TEMP AT FULL RATED POWER | 100.0 CELSIUS100.0 CELSIUS |
| AEHZ | MAXIMUM OPERATING TEMP | 150.0 CELSIUS |
| AEJA | THERMAL TIME CONSTANT IN SECONDS | 40.0 |
| AEJC | ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | 0.70 |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -75.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT-75.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT0.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT75.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.419 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT1.419 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 5.61 KILOHMS FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 6.435 KILOHMS SIXTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 6.963 KILOHMS SEVENTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.739 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT2.739 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 4.026 KILOHMS THIRD RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 4.785 KILOHMS FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -5.0 TO 5.0 ALL RESISTANCE-TEMPERATURE POINTS |
| AKNA | INCLOSURE TYPE | ENCAPSULATED |
| CQWD | ZERO POWER RESISTANCE | 3.300 KILOHMS3.300 KILOHMS |
| CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -5.0 TO 5.0 |
| STYL | STYLE DESIGNATOR | RODROD |
| TEST | TEST DATA DOCUMENT | 01295-CC202 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.).01295-CC202 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |