| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | 1.250 INCHES NOMINAL |
| ABJT | TERMINAL LENGTH | 3.770 INCHES MINIMUM |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.000 INCHES NOMINAL |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.625 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 0.312 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 0.875 INCHES NOMINAL |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.129 INCHES NOMINAL |
| AEHZ | MAXIMUM OPERATING TEMP | 200.0 CELSIUS |
| AEJA | THERMAL TIME CONSTANT IN SECONDS | 80.0 |
| AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 150.0 |
| AEJC | ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | -4.40 |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -60.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 300.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.2 OHMS EIGHTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 11.6 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 116.0 OHMS FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 13.1 OHMS SEVENTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 49.3 OHMS FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 24.7 OHMS SIXTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.2 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 261.0 OHMS THIRD RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.0 TO 10.0 ALL RESISTANCE-TEMPERATURE POINTS |
| AGAV | END ITEM IDENTIFICATION | TICONDEROGA CLASS CG (47); SPRUANCE CLASS DD (963); OLIVER PERRY CLASS FFG; VIRGINIA CLASS CGN (41); STURGEON CLASS SSN (637); FORRESTAL CLASS CV; WASP CLASS LHD; TARAWA CLASS LHA; NIMITZ CLASS CVN |
| AKNA | INCLOSURE TYPE | ENCAPSULATED |
| CQWD | ZERO POWER RESISTANCE | 725.000 OHMS |
| CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -5.0 TO 5.0 |
| STYL | STYLE DESIGNATOR | DISK ON SURFACE PLATE |
| TTQY | TERMINAL TYPE AND QUANTITY | 1 WIRE LEAD |