| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABJT | TERMINAL LENGTH | 2.000 INCHES NOMINAL |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.080 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 0.130 INCHES NOMINAL |
| ADAT | BODY WIDTH | 0.070 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 0.130 INCHES NOMINAL |
| AEBT | TERMINAL DIAMETER | 0.010 INCHES NOMINAL |
| AEHX | MAXIMUM POWER DISSIPATION RATING | 0.028 WATTS |
| AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 CELSIUS |
| AEHZ | MAXIMUM OPERATING TEMP | 125.0 CELSIUS |
| AEJA | THERMAL TIME CONSTANT IN SECONDS | 6.00 |
| AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 2.8 |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -15.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 100.0 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 148.0 OHMS FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 67.5 OHMS SIXTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 7.38 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.27 KILOHMS THIRD RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 34.5 OHMS SEVENTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 360.0 OHMS FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.0 TO 10.0 ALL RESISTANCE-TEMPERATURE POINTS |
| AKNA | INCLOSURE TYPE | ENCAPSULATED |
| CBME | CUBIC MEASURE | 0.001 CUBIC INCHES |
| CQWD | ZERO POWER RESISTANCE | 1.000 KILOHMS |
| CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| SFTT | SURFACE TREATMENT | SOLDER TERMINAL |
| STYL | STYLE DESIGNATOR | WAFER |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |