| AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
| ABJT | TERMINAL LENGTH | 2.000 INCHES NOMINAL2.000 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 0.050 INCHES NOMINAL0.050 INCHES NOMINAL |
| ADAT | BODY WIDTH | 0.050 INCHES NOMINAL0.050 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 0.012 INCHES NOMINAL0.012 INCHES NOMINAL |
| AEBT | TERMINAL DIAMETER | 0.006 INCHES NOMINAL0.006 INCHES NOMINAL |
| AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 CELSIUS25.0 CELSIUS |
| AEHZ | MAXIMUM OPERATING TEMP | 150.0 CELSIUS150.0 CELSIUS |
| AEJA | THERMAL TIME CONSTANT IN SECONDS | 3.03.0 |
| AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 1.41.4 |
| AEJC | ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | -5.40-5.40 |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -25.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT-25.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -50.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT-50.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT0.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT150.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 175.0 CELSIUS NINTH RESISTANCE-TEMPERATURE POINT175.0 CELSIUS NINTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT125.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT100.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT75.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT50.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 200.0 CELSIUS TENTH RESISTANCE-TEMPERATURE POINT200.0 CELSIUS TENTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.8 KILOHMS SEVENTH RESISTANCE-TEMPERATURE POINT1.8 KILOHMS SEVENTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 15.0 MEGOHMS FIRST RESISTANCE-TEMPERATURE POINT15.0 MEGOHMS FIRST RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 460.0 KILOHMS THIRD RESISTANCE-TEMPERATURE POINT460.0 KILOHMS THIRD RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 490.0 OHMS NINTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 850.0 OHMS EIGHTH RESISTANCE-TEMPERATURE POINT850.0 OHMS EIGHTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 9.0 KILOHMS FIFTH RESISTANCE-TEMPERATURE POINT9.0 KILOHMS FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 280.0 OHMS TENTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.0 MEGOHMS SECOND RESISTANCE-TEMPERATURE POINT3.0 MEGOHMS SECOND RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.8 KILOHMS SIXTH RESISTANCE-TEMPERATURE POINT3.8 KILOHMS SIXTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 35.0 KILOHMS FOURTH RESISTANCE-TEMPERATURE POINT35.0 KILOHMS FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.0 TO 10.0 ALL RESISTANCE-TEMPERATURE POINTS |
| AEWK | MAXIMUM CURRENT RATING | 60.00 MILLIAMPERES |
| AKNA | INCLOSURE TYPE | UNINCLOSED |
| CBME | CUBIC MEASURE | 0.00003 CUBIC INCHES |
| CQWD | ZERO POWER RESISTANCE | 100.000 KILOHMS |
| CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| SFTT | SURFACE TREATMENT | SOLDER TERMINAL |
| STYL | STYLE DESIGNATOR | SQUARE OR RECTANGULAR WAFER |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |