| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABJT | TERMINAL LENGTH | 1.125 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 0.150 INCHES NOMINAL |
| ADAR | BODY OUTSIDE DIAMETER | 0.070 INCHES NOMINAL |
| AEBT | TERMINAL DIAMETER | 0.020 INCHES NOMINAL |
| AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 CELSIUS |
| AEHZ | MAXIMUM OPERATING TEMP | 150.0 CELSIUS |
| AEJA | THERMAL TIME CONSTANT IN SECONDS | 8.0 |
| AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 2.5 |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -25.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 25.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 288.0 OHMS FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 336.0 OHMS SIXTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 388.0 OHMS SEVENTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 130.0 OHMS FIRST RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 164.0 OHMS SECOND RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 442.0 OHMS EIGHTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 200.0 OHMS THIRD RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 242.0 OHMS FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -5.0 TO 5.0 ALL RESISTANCE-TEMPERATURE POINTS |
| AKNA | INCLOSURE TYPE | ENCAPSULATED |
| CBME | CUBIC MEASURE | 0.001 CUBIC INCHES |
| CQWD | ZERO POWER RESISTANCE | 200.000 OHMS |
| CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -5.0 TO 5.0 |
| CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| STYL | STYLE DESIGNATOR | ROD |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |