| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABJT | TERMINAL LENGTH | 1.500 INCHES MINIMUM |
| ADAR | BODY OUTSIDE DIAMETER | 0.200 INCHES MINIMUM AND 0.300 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 0.260 INCHES MAXIMUM |
| AEBT | TERMINAL DIAMETER | 0.017 INCHES MINIMUM AND 0.023 INCHES MAXIMUM |
| AEHX | MAXIMUM POWER DISSIPATION RATING | 0.50 MICROWATTS |
| AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 CELSIUS |
| AEHZ | MAXIMUM OPERATING TEMP | 125.0 CELSIUS |
| AEJA | THERMAL TIME CONSTANT IN SECONDS | 80.0 |
| AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 5.0 |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -15.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.4535 KILOHMS THIRD RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 47.073 OHMS SIXTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.9427 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 206.55 OHMS FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 25.653 OHMS SEVENTH RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 27.999 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 93.84 OHMS FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.180 INCHES MAXIMUM |
| AKNA | INCLOSURE TYPE | ENCAPSULATED |
| CQWD | ZERO POWER RESISTANCE | 510.000 OHMS |
| CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -1.0 TO 1.0 |
| STYL | STYLE DESIGNATOR | SPHERICAL |
| TEST | TEST DATA DOCUMENT | 81349-MIL-R-23648 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-23648/1 GOVERNMENT SPECIFICATION |