| ABHP | OVERALL LENGTH | 8.312 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 2.000 INCHES NOMINAL |
| ABTD | MOUNTING SLOT WIDTH | 0.219 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 7.000 INCHES NOMINAL |
| ADAT | BODY WIDTH | 5.500 INCHES NOMINAL |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 7.312 INCHES NOMINAL |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 4.750 INCHES NOMINAL |
| AFGA | OPERATING TEMP RANGE | -55.0 TO 85.0 CELSIUS |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 30.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 30.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 30.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 500.0 MILLIVOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 500.0 MILLIVOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 500.0 MILLIVOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNF |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 SLOT SECOND FUNCTION |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD(S) FIRST FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 THREADED STUD INPUT FIRST FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 THREADED STUD OUTPUT SECOND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 130.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 130.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 130.0 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| CQJX | NOMINAL THREAD SIZE | 0.190 INCHES |
| CQRG | BODY MATERIAL | METAL |
| CRST | BODY SURFACE TREATMENT | TIN |
| CTJS | UNPACKAGED UNIT WEIGHT | 8.312 POUNDS NOMINAL |
| STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |