| ABKW | OVERALL HEIGHT | 2.470 INCHES MINIMUM AND 2.530 INCHES MAXIMUM |
| ADAQ | BODY LENGTH | 3.470 INCHES MINIMUM AND 3.530 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 1.470 INCHES MINIMUM AND 1.530 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 2.470 INCHES MINIMUM AND 2.530 INCHES MAXIMUM |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 3.000 INCHES NOMINAL |
| AECR | VIBRATION RESISTANCE RANGE IN HERTZ | +5.0 TO 500.0 |
| AFGA | OPERATING TEMP RANGE | -55.0 TO 85.0 CELSIUS |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.75 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.75 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.75 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE-RESISTANCE 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE-RESISTANCE 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE-RESISTANCE 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED HOLE(S) SECOND FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 TAB, SOLDER LUG OUTPUT SECOND FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 WIRE LEAD INPUT FIRST FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 208.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 208.0 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 208.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |