| ABHP | OVERALL LENGTH | 2.750 INCHES MAXIMUM |
| ABKW | OVERALL HEIGHT | 2.270 INCHES MAXIMUM |
| ABMK | OVERALL WIDTH | 1.980 INCHES MAXIMUM |
| ADAQ | BODY LENGTH | 2.520 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 1.750 INCHES MAXIMUM |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.176 INCHES NOMINAL |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.485 INCHES NOMINAL |
| AFGA | OPERATING TEMP RANGE | -55.0 TO 125.0 CELSIUS |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 1ST RADIO INTERFERENCE LOCATION NOT OTHERWISE SPECIFIED |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.05 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.1 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.1 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.5 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 12 WIRE HOOK INPUT FIRST FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 12 WIRE HOOK OUTPUT SECOND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 28.0 VOLTS DC 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 28.0 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 28.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| CQRG | BODY MATERIAL | METAL |
| STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ADJACENT SURFACES |