| ABKW | OVERALL HEIGHT | 4.560 INCHES MAXIMUM |
| ABMK | OVERALL WIDTH | 3.500 INCHES MAXIMUM |
| ADAQ | BODY LENGTH | 5.500 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 1.250 INCHES MAXIMUM |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.875 INCHES NOMINAL |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 2.875 INCHES NOMINAL |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 1.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 1.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 1.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 0.95 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 0.95 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 0.95 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.0 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 TAB, SOLDER LUG INPUT-OUTPUT LOCATION NOT OTHERWISE SPECIFIED |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 360.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 600.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 230.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| CQJX | NOMINAL THREAD SIZE | 0.380 INCHES |
| CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
| FEAT | SPECIAL FEATURES | NUCLEAR HARDENED CRITICAL DESIGN |
| STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ADJACENT SURFACES |