| AFGA | OPERATING TEMP RANGE | -55.0 TO 125.0 CELSIUS |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 30.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 30.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 30.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 1ST RADIO INTERFERENCE AND 6.0 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 2ND RADIO INTERFERENCE AND 6.0 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 3RD RADIO INTERFERENCE AND 6.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHCG | MAXIMUM TEMP RISE | 40.0 CELSIUS |
| AKNA | INCLOSURE TYPE | ENCASED |
| CBBL | FEATURES PROVIDED | NUT AND WASHER |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 THREADED STUD INPUT FIRST FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 THREADED STUD OUTPUT SECOND FUNCTION |
| CQDZ | MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE | 500.0 VOLTS AT SEA LEVEL |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 2ND RADIO INTERFERENCE AND 600.0 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 1ST RADIO INTERFERENCE AND 600.0 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 3RD RADIO INTERFERENCE AND 600.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| CQRG | BODY MATERIAL | METAL |
| CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 1.2 KILOVOLTS AT SEA LEVEL |
| CRST | BODY SURFACE TREATMENT | TIN |
| FEAT | SPECIAL FEATURES | THREE FILTERED FUNCTIONS |