| AAQL | BODY STYLE | SINGLE POLE TYPESINGLE POLE TYPE |
| ABTD | MOUNTING SLOT WIDTH | 0.103 INCHES NOMINAL0.103 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 6.000 INCHES NOMINAL6.000 INCHES NOMINAL |
| ADAT | BODY WIDTH | 1.500 INCHES NOMINAL1.500 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 3.156 INCHES NOMINAL3.156 INCHES NOMINAL |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 5.125 INCHES NOMINAL5.125 INCHES NOMINAL |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.172 INCHES NOMINAL0.172 INCHES NOMINAL |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.880 INCHES NOMINAL4.880 INCHES NOMINAL |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.397 INCHES NOMINAL1.397 INCHES NOMINAL |
| AJEC | BOSS HEIGHT | 0.125 INCHES NOMINAL0.125 INCHES NOMINAL |
| AKPX | POLE QUANTITY | 11 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 SLOT AND 4 SLOT AND 2 UNTHREADED HOLE(S)2 UNTHREADED HOLE(S) |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES AC AND 20.0 AMPERES AC AND 20.0 AMPERES DC SINGLE LOCATION20.0 AMPERES DC SINGLE LOCATION |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 480.0 AC AND 480.0 AC AND 250.0 DC SINGLE LOCATION250.0 DC SINGLE LOCATION |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 15000.0 AC AND 15000.0 AC AND 10000.0 DC SINGLE LOCATION10000.0 DC SINGLE LOCATION |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATIONOVERCURRENT SINGLE LOCATION |
| CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC SINGLE LOCATIONTHERMAL-MAGNETIC SINGLE LOCATION |
| CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS SINGLE LOCATIONINSTANTANEOUS SINGLE LOCATION |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION125.0 SINGLE LOCATION |
| CPRQ | RESET METHOD | MANUALMANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREETRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE1 TOGGLE |
| CPRW | ACTUATOR FUNCTION | TRIP-RESETTRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONEAT POLE ONE |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | GENERAL PURPOSEGENERAL PURPOSE |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 40.0 CELSIUS NOMINAL SINGLE LOCATION40.0 CELSIUS NOMINAL SINGLE LOCATION |
| FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION60.0 SINGLE LOCATION |
| MATT | MATERIAL | PLASTIC CASEPLASTIC CASE |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 COMPRESSION2 COMPRESSION |