| AAQL | BODY STYLE | SINGLE POLE TYPESINGLE POLE TYPE |
| ABXD | BUSHING LENGTH | 0.332 INCHES MINIMUM AND 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM0.380 INCHES MAXIMUM |
| ADAQ | BODY LENGTH | 1.562 INCHES MAXIMUM1.562 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 0.625 INCHES MAXIMUM0.625 INCHES MAXIMUM |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.906 INCHES MAXIMUM0.906 INCHES MAXIMUM |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGEDMODERATELY RUGGED |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.810 INCHES MAXIMUM1.810 INCHES MAXIMUM |
| AKPX | POLE QUANTITY | 11 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING WITH PANEL SEAL1 THREADED BUSHING WITH PANEL SEAL |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE |
| BBRJ | SPECIAL HANDLING FEATURE | MAGNETICMAGNETIC |
| CBBL | FEATURES PROVIDED | HIGH INRUSH PROTECTIONHIGH INRUSH PROTECTION |
| CMLP | THREAD QUANTITY PER INCH | 3232 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 1.0 AMPERES AC AND 1.0 AMPERES AC AND 1.0 AMPERES DC SINGLE LOCATION1.0 AMPERES DC SINGLE LOCATION |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC AND 240.0 AC AND 50.0 DC SINGLE LOCATION50.0 DC SINGLE LOCATION |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 300.0 AC AND 300.0 AC AND 500.0 DC SINGLE LOCATION500.0 DC SINGLE LOCATION |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATIONOVERCURRENT SINGLE LOCATION |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATIONMAGNETIC SINGLE LOCATION |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATIONTIME DELAY SINGLE LOCATION |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 135.0 SINGLE LOCATION135.0 SINGLE LOCATION |
| CPRQ | RESET METHOD | MANUALMANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREETRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE1 TOGGLE |
| CPRW | ACTUATOR FUNCTION | TRIP-RESETTRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONEAT POLE ONE |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATIONSERIES TRIP SINGLE LOCATION |
| CQJX | NOMINAL THREAD SIZE | 0.375 INCHES0.375 INCHES |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.055 MINIMUM AT 200 PCT AND 0.055 MINIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT SINGLE LOCATION0.950 MAXIMUM AT 200 PCT SINGLE LOCATION |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND FUNGUS RESISTANT AND VIBRATION RESISTANT AND VIBRATION RESISTANT AND HERMETICALLY SEALED AND HERMETICALLY SEALED AND MOISTURE RESISTANT AND MOISTURE RESISTANT AND SHOCK RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOFSALT SPRAY PROOF |
| CTJS | UNPACKAGED UNIT WEIGHT | 50.0 GRAMS NOMINAL50.0 GRAMS NOMINAL |
| FREQ | FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION400.0 SINGLE LOCATION |
| TEST | TEST DATA DOCUMENT | 81349-MIL-PRF-39019 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).81349-MIL-PRF-39019 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| THSD | THREAD SERIES DESIGNATOR | UNEFUNEF |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE HOOK2 WIRE HOOK |
| ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-PRF-39019/1 GOVERNMENT SPECIFICATION81349-MIL-PRF-39019/1 GOVERNMENT SPECIFICATION |