| AAJD | THREAD CLASS | 2A FIRST MOUNTING FACILITY |
| AAJD | THREAD CLASS | 2A SECOND MOUNTING FACILITY |
| AASA | THREAD LENGTH | 0.500 INCHES NOMINAL SECOND MOUNTING FACILITY |
| AASA | THREAD LENGTH | 0.688 INCHES NOMINAL FIRST MOUNTING FACILITY |
| ABHP | OVERALL LENGTH | 6.125 INCHES NOMINAL |
| ABNB | FIRST FLAT LENGTH | 0.438 INCHES NOMINAL SINGLE ACTUATOR |
| ABNC | FLAT HEIGHT | 0.218 INCHES NOMINAL SINGLE ACTUATOR |
| ABWV | SHAFT DIAMETER | 0.250 INCHES NOMINAL SINGLE ACTUATOR |
| ABXF | SHAFT LENGTH | 0.562 INCHES NOMINAL SINGLE ACTUATOR |
| ADAV | OVERALL DIAMETER | 2.000 INCHES MAXIMUM |
| AFBH | INDIVIDUAL SECTION QUANTITY | 9 |
| AFDC | NONTURN DEVICE TYPE | SLOTTED BUSHING AT 12:00 OCLOCK |
| AJZE | SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
| AKPX | POLE QUANTITY | 2 EACH SECTION PERIPHERY |
| AKPY | THROW QUANTITY | 4 EACH SECTION PERIPHERY |
| ALAQ | MOUNTING FACILITY CIRCLE RADIUS | 0.719 INCHES NOMINAL SECOND MOUNTING FACILITY |
| AXGY | MOUNTING METHOD | THREADED BUSHING FIRST MOUNTING FACILITY |
| AXGY | MOUNTING METHOD | THREADED STUD(S) SECOND MOUNTING FACILITY |
| CMLP | THREAD QUANTITY PER INCH | 32 FIRST MOUNTING FACILITY |
| CMLP | THREAD QUANTITY PER INCH | 40 SECOND MOUNTING FACILITY |
| CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SECOND MOUNTING FACILITY |
| CQJX | NOMINAL THREAD SIZE | 0.469 INCHES FIRST MOUNTING FACILITY |
| CQMK | CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL |
| CQRQ | SHAFT FLAT/SLOT ANGULAR LOCATION | 90.0 DEGREES FROM NONTURN DEVICE SINGLE ACTUATOR |
| CQYJ | MOUNTING FACILITY PATTERN | THREE POSITION CIRCULAR SECOND MOUNTING FACILITY |
| CRJH | SWITCH ACTUATOR INDEXING POSITION QUANTITY | 4 SINGLE ACTUATOR |
| CRSJ | SHAFT TYPE | ROUND, FLATTED SINGLE ACTUATOR |
| CSCF | TERMINAL TYPE | SCREW |
| CSHW | CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES EACH SECTION PERIPHERY |
| CSLC | SWITCH ACTUATOR POSITIONING INCREMENT | 45.0 DEGREES SINGLE ACTUATOR |
| CTDN | SWITCH ACTUATOR STOP DEVICE TYPE | ADJUSTABLE STOP SINGLE ACTUATOR |
| CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL |
| STYL | STYLE DESIGNATOR | TAP, CIRCULAR, BUSHING MOUNT |
| THSD | THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SECOND MOUNTING FACILITY |
| THSD | THREAD SERIES DESIGNATOR | UNS FIRST MOUNTING FACILITY |