| ABHP | OVERALL LENGTH | 3.660 INCHES MAXIMUM |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.090 INCHES MINIMUM AND 3.110 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.090 INCHES MINIMUM AND 3.110 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| ABKW | OVERALL HEIGHT | 4.440 INCHES MAXIMUM |
| ABMK | OVERALL WIDTH | 3.660 INCHES MAXIMUM |
| ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.191 INCHES MINIMUM AND 0.211 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AJSS | FREQUENCY IN HERTZ | 47.0 MINIMUM AND 63.0 MAXIMUM |
| AKDX | WINDING QUANTITY | 1 |
| AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
| APCN | COIL QUANTITY | 1 |
| APNP | DUTY TYPE | CONTINUOUS |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CBME | CUBIC MEASURE | 59.476 CUBIC INCHES |
| CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| CRXH | TIME DELAY | 0.05 SECONDS MAXIMUM FIXED OPERATE TIME |
| CRXH | TIME DELAY | 0.125 SECONDS MAXIMUM FIXED RELEASE TIME |
| CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 120.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 120.0 AMPERES AC INDUCTIVE LOAD |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 120.0 AMPERES AC RESISTIVE LOAD |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 AC |
| CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES DC RESISTIVE LOAD |
| CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC LAMP LOAD |
| CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES DC INDUCTIVE LOAD |
| PMLC | PRECIOUS MATERIAL AND LOCATION | TERMINALS SILVER |
| PRMT | PRECIOUS MATERIAL | SILVER |
| TTQY | TERMINAL TYPE AND QUANTITY | 6 THREADED STUD ALL FUNCTIONS |