| ABHP | OVERALL LENGTH | 2.400 INCHES MAXIMUM |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.365 INCHES MINIMUM AND 1.385 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| ABKW | OVERALL HEIGHT | 3.032 INCHES MAXIMUM |
| ABMK | OVERALL WIDTH | 2.313 INCHES MAXIMUM |
| ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.148 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AGAV | END ITEM IDENTIFICATION | E-3 FACS RAOV |
| AKDX | WINDING QUANTITY | 2 |
| AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
| APCN | COIL QUANTITY | 1 |
| APNP | DUTY TYPE | CONTINUOUS |
| APNQ | ARC QUENCHING METHOD | AIR |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CBBL | FEATURES PROVIDED | LATCHING CONTACTS |
| CBME | CUBIC MEASURE | 16.831 CUBIC INCHES |
| CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| CRXH | TIME DELAY | 0.025 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
| CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 200.0 AC AND 28.0 DC |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 29.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 20.0 AMPERES AC AND 20.0 AMPERES DC LAMP LOAD |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 40.0 AMPERES AC AND 40.0 AMPERES DC MOTOR LOAD |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 60.0 AMPERES AC AND 60.0 AMPERES DC INDUCTIVE LOAD |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 60.0 AMPERES AC AND 60.0 AMPERES DC RESISTIVE LOAD |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 200.0 AC AND 28.0 DC |
| CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.5 AMPERES AC AND 1.5 AMPERES DC INDUCTIVE LOAD |
| CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES AC AND 3.0 AMPERES DC RESISTIVE LOAD |
| CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES AC AND 500.0 MILLIAMPERES DC LAMP LOAD |
| TEST | TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| TTQY | TERMINAL TYPE AND QUANTITY | 11 SOLDER STUD ALL FUNCTIONS |
| ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-6106/11 GOVERNMENT SPECIFICATION |